drayton

  1. R

    Wiser Smart TRV Issues

    There appears to be a few posts on Wiser TRV's. Ridiculous flaw in the Drayton Wiser system This one is for schedules changing and opening vales at the wrong time. and another on the schieder wiser forum. Wiser TRV not fully closing I have a system with 9 x smart TRV's fitter Oct 22. All...
  2. G

    Installation of Drayton Wiser system

    My first post in this thread. I wanted better control of a panel heater in main bedroom. Downstairs is heated by ASHP to water underfloor heating. Upstairs by panel heaters with no timing facilities. Space limitations meant I couldn’t find the right size panel heater with a timer for...
  3. S

    Help wiring a new thermostat (Meross MTS200B)

    I am replacing my old Drayton RTS1 thermostat with the Meross MTS200B and I don't get the heating switching on. I thought it was going to be straightforward but at this point better to ask for help than screwing something. The old thermostat wiring is this one: The new thermostat has this...
  4. M

    Replacing a Drayton CombiStat Thermostat to Meross MTS200B WiFi Thermostat

    Hi, Need a little guidance, trying to replace my analogue Drayton CombiStat to a Meross MTS200B, however I can’t get it to work, fires the boiler up then cuts off and cycles on and off. This is how I’ve wired it; N (neutral) wire to Terminal 1 on MTS200B; L (live) wire to Terminal 2...
  5. handaloo2

    Help with Drayton Wiring

    Hey All, hoping to get me past the last hurdle of a Drayton Install Kit 1. I currently have a 2 Zone system, however the upstairs zone valve has been opened by a plumber as I really didn't need two zones. 2 year old Ideal boiler. Bought a Wiser Kit 1 and fitted it today. Images here Based on...
  6. W

    Ridiculous flaw in the Drayton Wiser system

    I came accross what I consider a ridiculous flaw in the Drayton Wiser system which I have requested Drayton to address. I had deactivated the schedules for all rooms while the system was being worked on so no rooms had an assigned climate schedule. The system had been fine in this off state for...
  7. M

    Drayton Wiser retrofit - Rads + Underfloor Heating - Which HubR Kit?

    Hi I've just moved to a new house and I’m looking to replace my current heating system controls with a Drayton Wiser smart system. I have an Ideal Vogue Max System 32 boiler with water tank, a basic Drayton thermostat that controls hot water on a timer and a Salus thermostat. I also have a...
  8. M

    CH on constantly - related questions...

    We have an old Potterton Suprima 100L system boiler. Having just had our PCB replaced (can anyone give me a rough cost for that? I feel we've been overcharged!), our CH is running all the time. We're left having to switch it on & off at mains. Second opinion from another engineer feels it is...
  9. F

    Secure Channelplus H27XL to Drayton Wiser Hub (WT734R)

    Hi, I've got Secure ChannePlus H27XL which I want to swap with Drayton Wiser Hub (WT734R - three channel) Could anyone please help me with the wiring of these below? (N & L I can see how to wire clearly) Here is a diagram for Secure ChannelPlus H27XL: And here is a diagram for Drayton Wiser...
  10. R

    Moved into first home, wireless thermostat missing

    Hello all, Moved into my first home a few days ago and discovered quickly that the thermostat is missing. We have the ‘receiver’ (connected to boiler) but no adjustable thermostat. I have pictured what is in the house, to turn the boiler on we have to use the override button. Am I right in...
  11. B

    Hive to Drayton Wiser

    Hey, Looking to switch over from hive to drayton wiser. Based on wiring diagrams it looks like the terminals line up 1-1 but would like someone to confirm. Unsure if i need to bridge live to common (terminal 1) given that there's already a connection to COM.
  12. LaurelLeaf

    Drayton Digistat+3 to Google Nest E

    ….Solved…. Complete newbie here! I am wanting to change my Drayton Digistat+3 to a Google Nest E. Confused with the wires, can anyone advise or is it incompatible? The boiler is a Logic Combi ES30. Thanks so much in advance!
  13. A

    Change of heating controller - wiring question

    Hi, I could use some advice on how to convert my current heating system to the Wiser platform please. I currently have a combi boiler which provides both heating and hot water from its ‘heating’ circuit (the separate ‘hot water’ circuit is used to provide hot water to a part of the house not...
  14. A

    New Build - Dual Zone conversion to Single for Drayton Wiser

    All - hoping for some guidance please on wiring up a new Drayton Wiser system to what I believe is an "S Plan" system. I live in a new build, with an Ideal Logic Combi 35 downstairs, with 2 heating zones - one for downstairs, one for upstairs. There is a (wired) battery powered ESI ESRTP4...
  15. A

    New MA1 Oscillating

    I have a 22 year old oil fired standard non-pressurised system with Drayton MA1 3 way valve and 'Lifestyle' connection system. A couple of years ago I replaced the old controller and some of the rad TRVs with the "Wiser" controller. Recently this started banging when going from mid position to...
  16. N

    Drayton LP711 Backplate wiring for Combi boiler

    Hi Community, I hope you can help with this one..? My Ideal Isar HE24 recently failed. Hot water, but no heating. Home insurance sent a man - he said the LP711 timeswitch was at fault and did a temporary fix as an override. So now, when the boiler is switched on the central heating is on...
  17. M

    Adding Drayton Wiser TRVs to a NEST setup

    Hi, Hoping someone can help as I have looked everywhere without success. My setup... I have a fairly new NEST setup that controls hot water and central heating from a Valliant ECOtek plus. I have a megaflow in the loft (probably not relevant). All radiators are on a single circuit. What I'm...
  18. O

    Drayton Wiser controls

    Adding a gas boiler to my baroque heating system (thermal store, woodburner, plate hex for dhw) and looking at control options. The system is plumbed so that the woodburner always heats the thermal store. There are manual valves to allow the gas boiler to heat the store only (rads then run from...
  19. A

    Replace Drayton with Nest - wiring?

    Hi, I'm not sure if my programmer can be replaced with a 3rd gen Nest? Google website says my wiring means no, but I don't believe that's true. Do I need to modify any wires or add anything? I know there's threads discussing similar, but I'm still not sure. I have a Drayton (British Gas UP2)...
  20. matburton

    Boiler backplate - Hot water needed for heating

    Hi, I have a pretty old gas boiler system, it's a two channel setup. Oddly for the central heating to work the hot water must also be on :confused: Recently I've swapped out the mechanical timer with a Drayton Wiser Hub. So for the first time I now have a thermostat (y) But that leads to a...
Back