ignition

  1. M

    HELP! WEIRD CAR WONT STAY RUNNING SOMETIMES

    So I have a weird problem on my golf 1.9 TDI 2007, when I switch the ignition on the car starts up however as soon as I let go of the key SOMETIMES the engine will shut off. Sometimes the car will stay running no problem. When the engine shuts off i have to switch ignition to on to start car...
  2. L

    Why is this Vailliant ecoTEC boiler immediately shutting itself down?

    This is a Vaillant ecoTEC plus 831. It completely shuts down (screens off etc) at instant of heat demand. Never ignites. After turning it back on, even if no heat demand is made it will still shut itself down in a minute or so. Also any time it shuts down you will not be able to turn it on again...
  3. S

    Baxi system 35/80

    Hi, I have this boiler in a house I just moved into, for the first week boiler was fine, now it doesn't fire up unless its reset about 4 times, pump comes on, fan comes on, gas valve clicks, but only a tiny flame, then goes out, each time I reset it the flame gets larger,, and as I said...
  4. Dan P

    Biasi M96 24SM/C2 Fault light that isn’t in manual.

    Hi all, My Biasi Boiler isn’t igniting and I have the following fault lights showing in sequence: I: flash green (shortest flash) II: red light for one second III: pulse green (slightly longer than I) Has anyone else come across this? From the manual it seems that this shouldn’t be possible...
  5. A

    Worcester Heatslave 20/25 no ignition

    Hi all, Our boiler packed up yesterday. Timer comes on, runs for a few seconds and then lockout. As far as I can tell, there's no attempt at ignition. I can hear the click from the controller after the fan has been running for a few seconds (which I assume is the signal to the ignition...
  6. A

    Ariston Clas HE 30 error code 501

    Hello, I am looking for some advice please. I have an Ariston Clas HE 30 boiler which is currently unable to detect the flame (error code 501). The first few times a reset managed to resolve the fault, but this no longer works. An engineer has suggested that there is a sub-board to the main...
  7. O

    Baxi Solo 2 50PF - Please Help!

    My boiler is playing up! What is happening is that my boiler starts up and runs for about 10 mins before the burner goes off. I then have to let the boiler cool down a bit before trying again, the boiler starts up without any issues then the cycle is repeated. Had a engineer around, he gave it...
  8. T

    Whirlpool gas hob akm200wh sparking continuously even without button

    My gas hob sparks continuously. I am aware that the button should be kept dry etc. But even if I remove the button unit from the plug in terminal, it continues to spark. I thought that it would be unable to spark without the button. Any suggestions as to the cause? Eg. Does it indicate a faulty...
  9. A

    Baxi 100HE Ignition Problem - has it changed with updated boards?

    My Baxi100he was locking out daily. It always started like a new boiler in the morning but on 2nd or third ignition it would lock out and after a while I noticed the fan wasn't spinning before ignition. The local gas engineer had serviced my boiler recently and told me it was in good condition...
Back
Top