Hi, was hoping for some advice
We are in a 1930s semi which has always struggled a bit with moisture and is very prone to mould forming. We are currently having a loft conversion done and it prompted me to think about solutions. Once seems to be PIV however we are obviously losing the majority...
I’ve attached a drawing to show the existing, temporary and final diagrams to help show the question.
The structural engineer has designed our loft with 2 floor steels and a ridge steel. The installation of the first floor steel (beam A) is simple, as nothing needs to be removed to install it...
Hello I have recently recovered a flat roof dormer with Sika Sarnafil here is my video covering the project has anyone else used this product before ?
Loft Dormer Flat Roofing Don’t Worry We Are Professionals
Sorry about the title couldn’t think of anything
Chimney breast/loft conversion
We have a 1930s semi in London, UK and are looking to do a loft conversion.
If possible we want to remove the chimney breast in the loft space to provide greater width to the new master bedroom.
We have received these plans from the structural engineer...
Hello, I'm just wondering how to tell if the joists in your loft are strong enough, whether just for storage or to use as a regular room?
I'm partly asking because we would like to eventually board the loft void above the rear part of our Edwardian house to use for storage, after insulating...
I'm not sure how to describe this quickly (sorry):
We had a lot conversion done.
After a time (quite a long time - don't remember how long exactly) a number of holes popped out - where the plaster board was screwed into the rafters.
I assumed this was fairly 'normal' settling of the new...
Hi,
We got a company to do a hip-to-gable loft conversion on our end of terrace house.
We have an option of 3 types of gable wall finish/construction
1. timber construction with render - not sure how this works typically. Is it a board that is attached to timber structure that the render is...
Hi all,
I am planning to do a loft conversion dimensions are 9m gable to gable and 7m wall plate to wall plate.
I got a quote for just under 14k for telebeams.
Looks a good system. But it is costly. I am wondering if steel spanning gable to gable will be cost effective or if the size of the...
Hi everyone,
I'm seeking advice regarding a dispute I'm having with my architect. I enlisted their services to create a plan for a dormer loft conversion on my 2-bedroom house. The project was divided into two stages: designing the rooms and roof, which went smoothly, and producing the...
Hi all,
Really hoping you can help with a problem with the roof of my newly converted loft. I had a torrid time with the build (over budget, overran, had to do loads myself) but it has been generally finished and has been signed off by building control.
The loft conversion is a full width flat...
Hi all,
I'm in the process of refurbishing my loft conversion which is really dated (no idea when it was built). I've removed the existing plasterboard walls and ceilings, removed the mineral wool insulation (in some areas there was barely any), and stripped it back to the exposed rafters...
Hi All,
I would like do to a semi-conversion of my loft to use it as an office space/man cave (tv, desk, etc.) and to store some boxes, and as any house owner does sooner or later, I worry that the ceiling will sooner or later come down for the weight (or worst, I will come down with the...
I just moved in a 4 bed 3 bath 80s built house which doesn't look like anything has been done to it since it was built. I have been reading about heating systems and think I have a vented system with regular boiler. There are 2 tanks in the loft which look like a large cold and small header. The...
I'm looking to convert our loft in our grade II listed property. My main concerns are around maintaining ventilation and finding an insulation solution.
The loft floor has already been boarded up using loft boards, and they have used 100 mm of wool insulation beneath. There is not enough head...
Hello, hoping someone can help please.
I saw on another forum (old thread therefore not getting a response) about the following regarding floor joists in a loft conversion -
“I gain 4 inches of head height by using the existing 4 inch floor joists (instead of new 8 inch joists as is the normal...
Hello,
We've planing permision for a loft conversion and extension. It's complicated by the fact we are not clear that we want the extension part (or at least all of ir) (lose to much outside space) and that we are not happy with the proposed floor plan. (the plans came with the house, we...
Hi there,
Link to images
https://imgur.com/a/HTqoKSX
We are looking at a terrace house that has had 6 walls removed across the first and second floor as well as a chimney stack removed. All building regs have been approved but I can't work out what's going on here. I assume the purlin used to...
Hi all
I’m in the process of a DIY loft conversion and don’t seem to find any information regarding the flashing of a dormer cheek against a party/brick wall.
please see photos attached, there will be hung plain 10x6 tiles on the dormer cheek, and the slates below the capping stones as shown...
Hello, sorry if this isn’t the right place, it’s my first time posting. I have a couple of question, both things I’m a little uneasy about. I have a builder working on a loft conversion and it has a large steal going across the ridge, my concern is it looks like that steal is only supported on...
Hi,
I have been slowly upgrading a converted loft in my victorian semi.
A couple of years ago I replaced the insulation in the rafters with PIR board. 100mm in between the rafters, 25mm underneath the rafter. 50mm gap between insulation in the rafters and batten for ventilation. At the...