pcb

  1. S

    Dead Henry PCB

    Hi My Henry Xtra has a dead PCB, The Henry is now running as I've bypassed the PCB, but I'd like to bring all the functionality back. The PCB Model No is 208428, I'd like to know if the later PCB model 208700 is a direct replacement and can be used in my Henry. I can't see any reason why not...
  2. mubsy81

    Ravensheat cs80 pcb fuse keeps blowing

    I have a issue with my ravensheat CS80. Pcb fuse keeps blowing. When i change the fuse, boilers works (hot water and central heating) for about between 15-30 mins then fuse pops. Any diagnosis or suggestions on where to look for the issue??
  3. C

    This site does not support DIY gas work (Ed.)

    .
  4. eveares

    Vaillant Ecotec 937 plus - Flu fan constantly on, LCD dead, No heating or hot water - Common fault or not?

    Had a short power cut earlier and when the power came back on, it looks like my Vaillant Ecotec 937 plus boiler died. My educated guess is either when the power went out or when the power came back on, the PCB on my boiler died, as now it is completely unresponsive (LCD dead, no heating or hot...
  5. A

    Ideal Instinct PCB

    I am aware I am not a gas engineer btw.. So long story short, my boiler is bricked. No display, nothing. Background is that I started fitting a Drayton Wiser Hub and thermostat. While I got it wired in fine the boiler failed to light when the Wiser Hub called for heat. It was getting late and...
  6. J

    Constant burning after Vailant PCB change

    British gas were out due to error codes on Vailant Ecotec Plus 618 yesterday. The PCB was changed and it was back burning again. The issue now seems to be that it hasn't stopped burning even though there is no call for water or heating. It looks like the temperature is going above the...
  7. W

    Repair of cooker hood PCB trace

    Hi. I’m wanting to repair the pcb on my cooker hood. I’ve attached a picture. My issue is that the tracts are a lot wider (around 5mm) than the jumper wire I was planning on using and I wasn’t sure if I should be using a lower gauge wire; I’ve was planning on using enamelled copper wire AWG ~29...
  8. G

    Old TV remote control needs some attention

    I have this old remote which I think has recently been a victim of the kids spilling something on it. As you'll see from the video, I have tried quite a few things to get it working (with some success), but now some of the topmost buttons no longer work. Hoping someone can provide some useful...
  9. R

    Is my Vaillant PCB dying?

    My Vaillant ecoTEC plus 618 display is always illuminated - previously it would go dark until I turned one of the temperature setting knobs. Not only that but now the temperature shown is flickering irregularly around the preset temperature (70°) and also flashing back to the outgoing...
  10. S

    PCB replacement - procedure/recommendations & exploring the topic.

    Considering a refurbished pcb from a company named Adlink (wembley) - £40 12 month warranty. What are fellow members views & experiences on using refurbished pcb's? Looking to open the topic up & explore it in discussion - to learn something new. I'm hoping to educate myself. It will be a bg...
  11. F

    Potterton Powermax HE - A01 fault

    I'm having a ignition fault on my Powermax HE boiler with error code A01. There is no 'visible' spark being generated on the ionisation probes (tested on new and existing probes - 3 different units, all gapped at 3mm so the fault isn't here). However the output from the PCB is registering 180v...
  12. mpaxton78

    Hotpoint FF PCB programming costs

    PCB got water damaged some time ago and when Hotpoint came out that refused to repair it due to the associated risks. I can get a new PCB fairly cheap but is there any way to get Hotpoint to reprogram it without it costing me £100+ which is what it appears to cost if I go via D&G. FF is only 3...
  13. L

    Why is this Vailliant ecoTEC boiler immediately shutting itself down?

    This is a Vaillant ecoTEC plus 831. It completely shuts down (screens off etc) at instant of heat demand. Never ignites. After turning it back on, even if no heat demand is made it will still shut itself down in a minute or so. Also any time it shuts down you will not be able to turn it on again...
  14. T

    How can a fix a key fob?

    I had my 2002 seat ibiza for a while now. When I bought it, the key fob wasn't working. I had a few days off and some spare time, so I decided to change the battery of the fob. It is a simple procedure and so it turned out. I swapped the battery out and tried the fob on the car. The 'LOCK'...
  15. T

    New PCB in older Vaillant ecoTEC plus 618 R1 not responding to request for heat

    Firstly, I'm not going to attempt to do any rewiring my self - but I do have a Gas Safe plumber on the job currently (waiting for an internal pipe that is leaking a bit), and I want to get informed on our situation so when he comes back we can get it sorted asap. I have a Y plan heating setup...
  16. K

    Boiler cycling on/off, but everything checks out

    Hi I have a precious boiler it seems, a Baxi Solo 3 PF 30. When calling for heat or hot water it will run fine for 15 minutes, and then it starts to cycle on and off at one minute intervals until the control stops calling. If I unclip the thermostat from the pipe it will run fine without...
  17. GBCTHORPE

    Intermittent Air Flow Fault

    Hello all, first post here so be gentle with me! I am the (not so) proud owner of an archaic WORCESTER 28CDI combi. Around Xmas time the boiler made some horrible loud grinding noises and then gave up completely, RGI came round and diagnosed the fan. Brand new fan fitted and then the boiler...
  18. L

    Which components are responsible for the power regulation circuit?

    Hello! I've got a problem with my washer dryer. Indesit WIDL 126. Sometimes, it doesn't turn as it should (it stops earlier) and then a relay clicks lots of times. This even happens durin spin cycle. On high spin you can hear that the motor suddendly doesn't get power (even the pump) and just a...
  19. C

    Zanussi ZDF14001WA dishwasher stuck on 2hr Programme

    Hi, I have a Zanussi ZDF14001WA dishwasher that is stuck on the 2hr programme which starts as soon as the dishwasher is closed - this usually requires the start button to be pressed. Switching between programmes on the dial doesn't seem to do anything. Just wondering if there are any button...
  20. T

    Logic Combi 24 - PCB keeps blowing

    Hi all, long-time lurker, first-time poster. I have a Logic Combi 24 that keeps breaking down. I'm covered by insurance (initially Ideal, then Homeserve, now Scottish Power - seemingly of decreasing quality, but you get what you pay for, I guess!). The issue I have is that within ~3 years, I'm...
Back