potteron

  1. Beasty1711

    Room thermostat upgrade wiring

    Hi, I’m just replacing my old PTR01 room thermostat with a Beok one and just wanted to double check the wiring before I pop something and then have to face the wrath of my wife… The old wires and diagram: And the new instructions: My assumption based on this: Blue (old 4) goes to N...
  2. S

    Potterton prima 50f boiler low pressure

    We've got a Potterton boiler with a hot water tank upstairs in an airing cupboard. Every year we close the valves on our radiators because they heat up even with the heating turned off. We've opened up the valves for the winter and tried bleeding the radiators but there's a lot of air in the...
  3. J

    Potterton Suprima to Hive

    hi, in October last year I fitted Hive against my Potterton Suprima boiler and it seemed all was fine. Following guidance from this site i thought i had it done. Now summer is here and I no longer need heating I’ve notice my water doesn’t get hot even though the light on the controller indicates...
  4. Ian o

    Hive replacement potterton EP2 help required

    Hi I’m looking at fitting a hive control in the place of a potterton EP2 I understand the live and neutral but can’t seem to get the wiring for the on/off for both the heating and water I have attached a photo of the current wiring Could someone please assist as to what order I should wire I...
  5. X

    Y-Plan Woes...

    Hi all, I'm looking for some help as I've exhausted all my resources and knowledge. Let me describe the current system... Boiler: Potterton Suprima 30 Timer: Center EHE0200160 Frost-Stat: Potterton PRT-100 Room-Stat: Potterton PR-100 Hot Water Cylinder: Joule Cyclone Indirect/Un-vented...
  6. N

    Upgrading to Hive

    Hi, Can anyone help with the wiring of my EP6002 programmer to Hive? I also want to remove the old thermostat and wires Thank you Vin
  7. H

    Potterton ep2002 to hive 2

    Wondering if anyone has any info on how to wire my potterton ep2002 central heating controller to my new hive 2, also I have a thermostat I have wired into my system somehow that ideally I would like disconnected and linked out at the source, any help would be great cheers
  8. W

    Potterton e168

    Hi all, i have a potterton 28 he+ that been giving me an random e168 errors. so far Ive replaced the actuator, diverter cartride, pressure switch, temp sensors pcb and room stat (salus wireless). doesn't happen as frequently now but still there. usually more after having used hot water. im...
  9. K

    Any engineers around Aberdeen who knows Potterton Puma 100e?

    Guys, is there any one here who know good engineer familiar with Potterton Puma 100e. Its fluctuating HW temperature and seems pointing towards scale in heat exchanger?? Hope not!!! So looking someone to actually diagnose the problem and if thats really a heat exchanger than replace the one...
  10. K

    Potterton 30 boiler flashing amber (calling heat) but doesn't ignite

    Hey guys I have just purchased a house and when i turn the 24hours button on the timer for the CH the potterton boiler calls for heat (flashing amber) but doesn't respond (fire up) however, a few hours later if i try it then it does or may not. Also I set the timer (honeywell) for the boiler...
Back