Hi,
We had a structural engineer visit and tell us the wall we wanted removed was load baring. It was a 3m wall between kitchen and dining room, front to back, parallel with joists. He said it was supporting the timber frame wall above (2.2m in length, directly above) and a joist sitting...
Hello all,
I posted a forum post here about a poor boiler install and have now asked roofers to have a look in the coming week at the crossbeam the engineers cut significantly when installing the boiler...
Hi all,
I saw this image online and I’m just curious to see if this is structurally a good method to join rafters on top of a ridge beam. In the photo you can see the rafters are beside each other and nailed rather than flush cut and butted up against each other and nailed. To me it has to...
I’ve attached a drawing to show the existing, temporary and final diagrams to help show the question.
The structural engineer has designed our loft with 2 floor steels and a ridge steel. The installation of the first floor steel (beam A) is simple, as nothing needs to be removed to install it...
Hi all,
We're first time buyers and have recieved our survey back. Its highlighted a few issues with the property which is makjnv us very nervous. I don't know if it sounds worse than it actually is , any advice would be greatly appreciated before we make the decision to carry out additional...
Evening all,
I am new to DIYnot but have had a read of some of the informative posts on the forums. I hope I can get some useful advice to help me navigate my current position in the best possible way. From the very start of our discussions with the architect and then subsequently the engineer...
Hi all,
Just a quick questiong for the experts out there.
We are planning on an extension and remodel of the back and side of our house (Please see plans attached).
We have received a few SE quotes where the beams to be used are different in number.
1. The first SE quote has been for 4...
Hi All,
Doing my first wall knock through since building a workshop and work has stopped due to padstone.
Our SE has written:
Min 500 x 100mm Padstone bridge across cut cavity in 7n block at 450mm vertical cr
And 400 x 100mm on the other side.
The pier itself is only 270mm which the builder...
I have just received planning permission for an integrated garage conversion into a study and shower room. I’m adding an internal door to the hall way, bricking up and popping a window in where the existing garage door is and adding a small window at the side. I am completely ignorant. I have...
Hi
Currently have a builder doing an extension on my home and it requires a 305 steel being installed on posts.
My aim/instruction was to 'hide' the beam but putting it higher in the property and the floor joists will then run into it.
We have a 305mm steel beam but the cavity wall is 1980s...
Good Evening,
I want to get in a structural engineer to have a look at a few cracks in and outside our house. Everyone I know doesn't think I need to be worried about any of them as they're not mirrored inside/out etc. However, for peace of mind, I wouldn't mind getting a professional opinion...
Hi All,
Looking for some advice please on this probate property to be purchased. It's going for £225k in West Midlands as a 1950s three-bedroom end of terrace with a ground floor extension, with a flat roof, split into two rooms (sitting room and utility room). The property generally needs...
Hi all. I'm new here, please go easy on me. I need you all the chippys, architect and builders advice on board and ASAP.
I've removed my chimney breast walls from top to bottom. I'm now left in the bedrooms with exposed Joists, which are 7x3 timber and 5 metres long.
I was hoping, is it...
Hello,
I am in the midst of purchasing my first home. The property is a 3 bed semi detached.
The property garage at the back was converted into a room and an extension/garage was built to the front (single storey)
Directly under the left side of the window (on the outside) at the back, you...
Hi all,
First time poster here. As a bot of back ground, im getting a new kitchen fitted.
The plumber, sub-contracted out by the builder, came around to do some work today. When I got back, I witnessed the following. He has essentially chased the wall (External gable end wall) through to...
We're looking to remove a load bearing wall, which is supporting one wall of a gabel, the floor above, ceiling above and roof above. I've sent our structural engineers calcs to my dad and we're both a bit concerned.
The above image shows the wall (and chimney to be removed). The wall is...
Hello,
have to repair an undersized and badly notched joist 38x175mm sitting in an intermediate floor connected to the ceiling below.
The joist is sagging but also has a slope resulting in a lower level support in the middle of the flat (double span joists).
A metal plate 8x150mm would be...
Hi there.
Structural Engineer question.
Would an engineer possibly do me a really nice favour and suggest some details for a splice joint?
My engineer has done most of my calculations for me, but I need to add a splice joint to an upright steel RSJ.
Unfortunately, the engineer is ill at the...