  1. M

    Honeywell 5-wire zone valve wiring (to Nest)

    Hi All I'm trying to replace Honeywell thermostats with Nest. I don't do this professionally (something similar-ish) but have a fair amount of experience. The wiring centre is simple, Neutral, Live and Earth and six wires from three existing thermostats (two each). I think the valves are...
  2. F

    Smart Thermostat recommendations?

    I'm looking to get a new combi boiler fitted soon, likely a Viessmann. The combi boiler will be servicing about 9 radiators (including 2 towel radiators) and 2 showers in a 3 bed flat. I'd like a smart thermostat system for this, but am a bit flummoxed by the options especially the zoning...
  3. S

    Zonal heating system question

    Hi all, I have a very basic heating system that I would like to upgrade. Basically, it consists of a Oil burner (non condenser) and two zone systems (downstairs and upstairs), plus hot water tank (which is part of the upstairs zone) There currently are no thermostats except what is on the...
  4. M

    Scantronic / Cooper Security 9651 Entry & Exit Routes

    Hi all, Newbie here - I've moved into a house with a Scantronic 9651 alarm (and 9940 LCD Remote Keypad). The alarm has been set with the front door to the house as the entry and exit point. All sensors are downstairs. That works fine for when we leave the house, but if I set it a night when...
  5. D

    Proposed sink proximity to combi?

    Am sorting my zonally challenged bathroom, the more learned of you may notice certain issues.. That bath is coming out, new bath position rotated 90% to to run along left wall with taps at exernal wall end, to left of window. With shower screen. The waste water outlet is below that window...
  6. D

    Washing machine in bathroom - outside zone 2

    What do the most recent regs say about washing machines in bathrooms? My (2.5m x 2.1m) ground floor bathroom and 1st floor kitchen need rearranging: obviously, the washing machine really needs to be in the bathroom (below the kitchen). The 2 main trips on the CU are RCD protected. Thank you...
  7. D

    Bathroom light move

    A cluster of 3 led lights, it's good because the bathroom gets very little natural light. But it's zonally conflicted in plan, being sited just outside the outer edge of the bath/shower It could do with going between the the next pair of joists but this would require extending the cables...
  8. phykell

    Teeing off in 15mm for Extension/Chase in Concrete

    Hi, My house is a combination of suspended (floorboards) floors and concrete and it currently has no central heating. I've worked out a route for the CH pipework which avoids all of the concrete areas except for one room which is an extension. I have two options as far as I can tell: 1. Dig...
  9. B

    Texecom Premiere Elite 24 - correct zone configuration?

    Hi - looking for advice on how to set the zones on my Texecom Premiere Elite 24 kit. 5 x PIRs, one each per zone (1 - 5), zones 6 - 8 linked out on board and also set to disabled. Zone 1 is the main hallway, keypad is in view of the PIR, zone type is Entry/Exit Zone 2 is the utility room - it's...
  10. M

    Hot water from storage cylinder leeching into radiators ?

    Hot water coming out of the hot water storage cylinder into upstairs radiators after heating/HW turns off and running out of hot water in the mornings. I have a Glow Worm 24HX Condensing boiler on the ground floor with a pump in the same cupboard, a hot water storage cylinder in the airing...
  11. M

    hot water temperature problem

    I have a Glow Worm 24HX Condensing boiler on the ground floor with a pump in the same cupboard, a hot water storage cylinder in the airing cupboard upstairs (Kingspan 1500 x 450 grade 3, 162 Litre. cylinder) in the eaves area I have another pump (both pumps are Salus MP200 domestic circulating...
  12. cwhaley

    Outside Wall Lights - Patio Door

    A while ago I put a wall light up on the back of my house next to the back door. I believe I did this safely and this was my method: I took a spur from a nearby socket, chased the new 2.5mm T&E wire in the existing conduit (straight up from the socket), took this along the wall (at 100mm away...
  13. H

    AccentaOptima G3 zone light flashes when setting alarm

    We have an old Optima G3 hard wired alarm system with an intermittent fault- when setting the alarm one of the red zone lights flashes and the beep tone is different. Sometimes it resets itself without any action from us and we can continue to exit with no problem and when we return all is ok...
  14. F

    texecom veritas or elite 24 zone type

    Hello, Is there an option or zone type to monitor a door using magnetic contact as follows: no PIN codes to be used. no arming or disarming to be done. and whenever the door is open the internal sounder keeps chiming or quacking, and once the door is closed the sound is stopped...
  15. D

    Quiet motorised zone valves - do they exist?

    Hi Read the forum loads in the past but first time posting... I've just had 2 Sunvic motorised zone valves fitted to control my new heating. One controls the under-floor in the living room, the other the rads in the rest of the house. The motors driving the valves to open / close make a...
  16. PhotographyJosh

    Galaxy 24h zone override

    Hi all, Just wondering if anyone could help me to figure out how to use a 24 hour zone on my Galaxy G2-20 whilst maintaining the ability to deactivate the zone when required? I have seen this done in a company I used to work for where the fire doors where monitored for breaches but one door...