floor

  1. J

    Advice on fix: Damp floor inside balcony doors.

    Hi, I am putting down new flooring on our top floor apartment (2007) that we just bought. One room has a balcony. It seems dampness is coming in from the balcony - particularly after rain [maybe that's obvious :o) ]. Is there any way to fix or mitigate this before putting down vinyl? Any...
  2. A

    Bump in my kitchen floor

    Hi A bump appeared in my Kitchen floor recently. After removing the lino there are two tiles that are being pushed up together to form a tent like bump. I called the Council as it is an ex council flat and they arranged a surveyor to come in The surveyor found the old gas connection on the other...
  3. 0

    Log Cabin Floor levelling

    I can’t decide which flooring option is best for a 5m x 3m log cabin I have built. The cabin is laid on a 15cm thick concrete pad but the pad has a deviation of 10mm in places. There’s a bit of a hump in the middle as it chucked it down with rain as it was being poured and I didn’t get it...
  4. J

    Suspended Floor Insulation

    Hi, I'm looking to insulate the suspended floor at ground level. There is a 3ft void underneath the floor. I've been looking at using this stuff, https://ybsinsulation.com/floor-insulation/suspended-timber/superquilt-suspended-timber/ I would be installing as show in the attached picture...
  5. George Hartshorn

    Underfloor heating advice

    I'm undergoing a renovation project and looking at installing some underfloor heating. It is a lower ground floor flat with a concrete slab for a floor. It's approx 50sqm and consists of a open plan kitchen/living room and a large bedroom. The current central heating system pipes are copper...
  6. George Hartshorn

    Routing electrics through floor or chase into walls?

    I am purchasing a lower-ground floor flat which currently has all of the plug sockets and wiring surface mounted in trunking. I'm undertaking a renovation project on the house soon so now is the time to get them hidden! I am looking at installing a wet UFH system between a concrete slab and my...
  7. George Hartshorn

    Should I break out the concrete slab in my flat? - help!

    I'm at a loss as to what decision I should make. I'm just in the process of buying a new lower ground floor flat in London which is approx 50sqm. Its been unoccupied for a few years and we will be renovating before we move in. In the late 80s the wooden floor was ripped out and replaced with a...
  8. L

    Flooring woodworm

    We recently purchased a three bed semi. The floorboards in the hallway are in terrible condition - the previous owners lifted the carpet 20 odd years ago and haven’t looked after them properly. the survey said the hallway has suffered historic woodworm (see pics). Do you think any can be...
  9. wilco88

    Glue and nail floorboards or just nail? Or screw?

    Hi, I have lifted the 1930's pine floorboards from my house. I plan to insulate underneath them and then re-lay and sand. Should I: 1. Glue and nail them down 2. Just nail them down 3. Screw and glue 4. Just screw Worried about squeeky floor boards. Any advice would be great. Thanks.
  10. M

    Laminate flooring/Concrete floor

    Hello all, Just wondering if I could get some advice please. I am planning on laying laminate flooring on a concrete floor. The current floor doesn't seem too bad as far as moisture is concerned. However, as a precaution, I would like to go with some form of underlay with a moisture barrier and...
  11. J

    Tiling on first floor wooden floor. What the best way?

    I have to start tiling my upstairs bathroom and got opposite opinion between sticking hardiebaker or using ditra matting before applying the floor tile. What your opinion on this and what would be the best reliable way? Thanks
  12. janieJones123

    Glue for laying floating engineered flooring

    I am going to be laying a floating, tongue and grooved engineered flooring in my bedroom. It's on the first floor and suspended timber subfloor. I was wondering what glue people would recommend for the T&G joints, or is any good weatherproof PVA glue sufficient? I would rather use something I...
  13. ahearsum

    bathroom plywood floor in one piece?

    I'm remodelling the bathroom (smallish 2m x 1.7) as a wetroom. I'm replacing the whole floor: 24mm ply, 6mm tile backer board, electrical underfloor heating, self levelling stuff, 10mm porcelain tiles (300x 600). I may be able to lay the whole ply board (apart from the tray former) as one piece...
  14. ahearsum

    Is this Vermiculite and is it dangerous?

    I'm remodelling my first floor bathroom and lifted the chipboard floor to find a load of small stones. An internet search suggested it my be Vermiculite and that it might not be that good for me if I breath in the dust. Does anyone have any experience or knowledge of this and if it is dangerous...
  15. JamesGibs0

    Floating Screed, cracks and movement

    We have had an extension and wet UFH installed across the whole ground floor (new and old). UFH in the new extension is clipped on top of celotex. UFH in the existing is embedded in an insulation board. - about 45m2 in total We've had a floating screed installed (Longfloor CT-25/F5) and 3...
  16. T

    Marley Tiles and DPM

    we're on the last leg of decorating our lounge and lifted the old laminate to find marley tiles underneath. We were just going to leave them and put carpet over the top but lots started lifting a couple of days later. Having had issues in our kitchen, weve removed tiles and applied wickes...
  17. LisaYP

    Screed over safety floor in wet room

    Hi, I have a wet room, (made when i had a grant because of spinal problems) and in it the floor is safety flooring, like the kind Alto do but its grooved like an embossed pattern in it. Its not smooth which is my problem. I dont have the spinal problems anymore and want to put a shower tray and...
  18. D

    Do you need subbase/sub base and sand under a screed kitchen floor?

    Hi! We were quoted for a floor to be smashed up and replaced with a new floor. The estimate described there being a sub base, sand then DPC, insulation and 65mm fibre screed. We were away the day it was prepped for the screeder, but when we had a peek under the dpc just before the screeder...
  19. L

    Suspended floor anchor bolt spacing

    It is proposed to create a storage room utilizing the roof void above an integral garage. The span is 9' (2740) Plan to use 6x2 (47x150) rough sawn treated timber joists hung from wall plates at 450mm centres with 1 (offset) row of noggins. (I've checked these against tables and this size timber...
  20. D

    Sub floor over conc. base: Any suggestions?

    I treated the conc. base with sikka rapid dpm, then put membrane or damp course under the stud soles. I'll cover the whole base with a taped seam membrane anyway. I was thinking of masonry screwing a couple of treated 38x63 CLS down flat directly on the membrane at the base of the stud wall to...
Back