oil boiler

  1. L

    Trianco TRO 15/19 MK3

    Hello there, Thanks for reading this - As the title suggests, I have a Trianco TRO 15/19 oil fired boiler, which has currently stopped working. The boiler has come to a complete stop, normally there is a green light to indicate mains supply and then when I switch the programmer to turn on...
  2. C

    Alpha Oil Boiler lockout intermittently

    Hi I have an Old (1992/3) ALPHA range / boiler - its has two ecoflam minor 1 Boilers - I had fuel oil delivered the other day and the next day it locked out. I reset it and after about 1-2 hours it locked out again. The boiler goes through its cycle and heats the water and every so often when...
  3. Mike15/19

    Lockout Worcester heatslave 15/19

    The problem is more burner related Worcester heatslave 15 19 oil boiler It is a bentone b9 burner made in 1999 With a danfoss bfp 21 l3 oil pump . The boiler will run fine with heating on but about 1 in every 3 or 4 times it goes to start up it will lock out , I will press the lockout button...
  4. kinning

    MOES WiFi Smart Thermostat, replacing a on/off switch

    Hi hope someone can help, I have read and got a lot of answers in the past, but couldn't sort this. I've purchased "MOES WiFi Smart Thermostat" from amazon, and need it t replace a simple on/off switch that controls the boiler. Pics below of inside the current switch. Wiring diagram for the new...
  5. K

    Keroscene combi boiler has stopped producing by-product water

    We have a Grant Vortex 36Kw combi keroscene burning boiler, which has two expansion vessels fitted to the heating side of the boiler. Recently we added a bit of pressure to one of the expansion vessels. Since then the boiler has stopped producing the by-product water that's produced when you...
  6. J

    Riello G5X Burner Not Igniting

    Hi, i was wondering if anyone can help me out with this. Recently got called to a breakdown on a Boulter Camray 3 with a Riello G5X burner. The boiler would purge, spark, and for a split second ignite only for the flame to fail. It doesn’t go into lockout, the fan continues to spin and it...
  7. N

    Trianco Contractor Combi 110 HE not firing

    Hello, We had a leak inside the boiler (now fixed) but since then the boiler will not fire up. The boiler fan will start but I do not hear the normal whoosh noise I would expect. I took the red plastic cover from the burner and there is no visible sign of water ingress, so I am not sure what...
  8. M

    Oil Boiler keeps turning on mystery... (DDC420 controller)?

    Hi, We've relatively recently bought a house with a DDC420 controller and are struggling to understand some of it's behaviour and wondered if anyone could help. The main problem at the moment is that the boilers seem to fire even when there shouldn't be any demand on them. An example from...
  9. Andrew Green

    Oil boiler no hot water

    We have no hot water and it sounds as if the boiler is failing to ignite (when the timer turns the boiler on for hot water we just get a repetitive pinging/banging noise and only lukewarm water, while the heating system is fine). We did not have this problem until 2 days ago. Before that...
  10. D

    Trianco Eurostar Flue

    Hi, Does anyone know if the Eurostar 90 requires a flue specifically for that boiler, or if a generic flue of the same dimensions would suffice? Proving to be tricky to source a flue for this old boiler. So far have found this one... https://www.bhl.co.uk/trianco-1000mm-horizontal-flue.html#...
  11. A

    Oil Boiler Lockout

    Hi guys, I’m having an issue with an HRM Wallstar oil boiler. I have completely replaced the burner for brand new but it is still going into lockout. The pressure is building up and it fires up then gradually the pressure drops off and goes into lockout, if I manually bleed off some oil before...
  12. A

    Enviromax Combi C35 Pressure Loss and Central Heating weirdness

    Hello I'm a new poster here, Boiler- Enviromax Combi C35 with Riello RDB Burner The central heating has been consistently loosing pressure over time and I have sorted many leaks since moving in the house but have discovered one small leak on a radiator that looses less than 15ml of water over...
  13. P

    Grant Vortex - oil boiler... smells like gas!

    Hi there - we have a Grant Vortex wall hung oil boiler. It's been giving us some problems locking out all the time, and we've had a plumber visit and carry out various things, which have got it working for a bit... and then it lock out again. So far, they've changed the photocell, the control...
  14. R

    Hive receiver wiring help - oil combi boiler

    Hi, I have moved to a house with a oil Combi boiler and a thermostat (Grant) which is on the wall in the kitchen. Can I replace this with my hive receiver do you know? I'm a joiner to trade so very limited ability with things like this although I replaced my old one but it was like for like...
  15. R

    Oil boiler problem

    Hi all, slight issue with a grant euroflame 50/90. Burner going to lockout, I've changed the oil pump due to it being seized , boiler then fired up, few hours later lock out light back on, motor working fine, checked all was spinning freely. Boiler making humming noise. Changed capacitor and...
  16. A

    Potterton Statesman overheat light when stat setting increased

    Hi, I have a Potterton Statesman oil boiler using its integrated stat for temp control. The boiler fires up as normal as far as the stat is set below half way (unfortunately not hot enough to heat up the house in cold weather). If the stat is set above half way, the overheat light (red one)...
  17. H

    OFCH water pump needs constant bleeding

    My water pump has started acting strange, it needs bleeding after every cycle of the burner. You can hear the water stop flowing and when you bled it there is hissing for a few seconds, after every cycle, then you hear the flow again What I've tried so far: bleed system where possible, plumber...
  18. G

    One boiler or two boilers, that is the question...

    Hi We live in a bungalow that has an old grant oil boiler (No gas, we live in the sticks) and we have converted the stables, which is not attached to the house, into a bar with underfloor heating. We have some options, hope someone can provide some advice A) single big, 70kw?, boiler to serve...
  19. M

    Best outdoor oil combi boiler and fitting price

    My old grandee oil combi boiler is now 14 years old and during that time it's had a few repairs on it and still going strong but I have yet to meet a engineer to say anything good about them. Anyways, the combi is now 14 years old and it's seen better days and unsure how many more years it can...
  20. S

    Can someone explain Return Temps to me?

    I've always just assumed that the colder the return to the boiler the more efficient the boiler would be (i.e. greater differential so heat transfer through manifold is faster). But I've come across direct evidence to the contrary (e.g. boiler recommends minimum 60 degree return, 'hearth' temp...
Back
Top