I’m looking at this UFH solution for an upcoming project on suspended timber floors.
https://www.omnie.co.uk/torfloor/
It’s the only solution I’ve found which gives a low floor build up and is designed to replace the structural floor.
It comprises a routed 22mm chipboard sheet with a foil...
A customer has asked for a quote for a garage conversion, one of the requests is to have underfloor heating, the problem is that they have asked for the electric mat system and the area is 40m2. is that even possible with the load on the wiring. it seems like a lot of cable under the floor. also...
Hi
I have underfloor heating pipes installed in between joists for first floor.
Wonder what anyone has used in the past for insulation between joists? Rock wool or Celotex boards? or any other insulation.
Realise the celotex route will be more expensive.
Thanks in advice.
Hi Guys,
I already posted that question on tilers forum, but got no answer so far...
We (my wife) has an idea about swapping kitchen and a living room... I got no problem with plumbing and electrics but she also want tiles and UFH in the new kitchen.
The current floor is wooden and...
Hi,
We have had an extension built and are having the layout of the house completey changed so thought it would be a good time to install underfloor heating. I'm a boiler guy by trade but have never installed UFH but it doesn't seem too complicated.
Firstly I assume that in the new extension...
Hi,
We are renovating our house - its currently been gutted and we are thinking of putting Wet Underfloor heating in the whole house and currently weighing up the options. The ground floor will definitely be UFH (concrete floor so will be 100mm celotex + pipes + screed + flooring.) and we are...
As part of a renovation, our plumber installed UFH in the main ground floor areas, as we were having new floors laid. Rads were installed in the rest of the house. The UFH is in two separate zones (separate flow monitors for each). Therefore, a 3 zone system in total.
The plumber left us with...
Almost a year ago I was trying to resolve a few issues with our underfloor - see orignal thread in plumbing here:
https://www.diynot.com/diy/threads/underfloor-heating-a-couple-of-issues.493454/
The meachancal side is fairly under control (!) now nut the control side - electrically, is still...
Hi
Anyone got any tips for laying our 20mm PE-RT underfloor heating pipes into aluminium spreader plates (200 mm centres)?
Specifically I'm after advice on how to get the pipe to be more flexible. The pipe is really stiff and very difficult to get it to fit around the bends.
I'm going to try...
Hi,
I've just moved into a flat with Devimat heating and am confused about the settings / display.
1. Should the mat switch off as soon as it reaches the end of the "on" time?
This morning, I noticed that the Devireg 550 controller in one of the rooms was showing the heating-up symbol about 40...
Hi, recently purchased a bungalow with UFH controlled by devireg 550s in every room.
They are all wired and the displays on, but no matter what i set the timers and temperatures to the heating is not kicking in when expected and appears to kick in randomly.
Downloaded several manuals and i...
Sorry, this is a nested question..
Old suspended 1960s floor comprises:
3" void, 3" timber heights (sat on engineering bricks, levelled with cement), floorboards.
Joist spacing sees 440mm approx inbetween joists. Joists are 2.5" wide.
Goals:
- insulate between timbers
- UFH: install over tray...
Hello UFH people. I am about to install a wet underfloor heating system
25mm 8:1 screed over celotex between joists @ 400 centers. Seems to be the best fit for our project.
I need to get the pipe work in soon so that the floor can go down. And then I’ll do a bit more research on manifolds/...
Ok. So I know that cost is a very subjective thing but I'm in the midst of a renovation - my first real project - and we're planning to tile most of our ground floor so to take the cold edge of the tiles, we're planning on installing electric underfloor heating.
We've had a quote for around...
Ok I am a beginner so may not get the terminology right so apologies in advance(part of the battle with DIY is know what questions to ask(the other part is know who to ask)) but from reading other posts I think I am in the right place. So hope you can help me
as the Title suggest I have and...
Hi,
I'm planning to install a thermal buffer store (to prevent my combi cycling) as part of my UFH on a building control ticket. I'm a professional engineer, and feel competent to install it safely.
However, I am unclear about part of the G3 requirements (so competency not quite there, but...
Hi,
I'm a new member here, but have been floating in the background for quite a while now.
I'm putting acoustic insulation and UFH into the floor of my first floor flat. I'm planning an approach inspired by an (acoustic) detail mentioned in building regulations document E, 3.102, which...
Hello every one,
I’m going to be making our en-suite in to a wetroom and want to use wet underfloor heating.
Do I tank the room then put the under floor heating on top of that or the other way round?
If any one has any recommendations on tanking products or wet underfloor heat please let me...
Нi Friends
I am Zmicer
I will show you a new project.
I hope it will be useful to everyone who builds a house.
Equipment did not work the proper way.
There were installation mistakes from the very beginning, and
Underfloor pipes of heating system were leaking.
We decided to replace radiator to...
Looking for advice on UFH as well as general heating system.
We have made the choice to get water underfloor heating in the middle of our refurb works for the kitchen. Rather than placing PVC pipes in plastic castellated floor panels, we will have them routed between joists and on top of...