vaillant

  1. H

    Vaillant EcoTec plus...no taps to add pressure

    So I have a F.75 error code on my Vaillant ecotech plus and my pressure gauge is low. I watch the you tubes videos of what to do and it seems straightforward. Except I have no taps to turn under my boiler. They are just not there. Any advice on how I get heat tonight? What can I use to open...
  2. Dan27

    VRC 470

    Hi Guys, New to these forums and new to the Vaillant VRC470 weather compensator! I've seen many other threads on people trying to get there heads around how this system works. I was wondering if anyone could help with the following: 1) How do I know whether I have two heating zones, I have...
  3. S

    Nest 3rd Gen and Vaillant ecotec 624 y-plan system

    Hi - I know there are multiple post regarding Next setup and connection however I'm unable to find any information on my specific issue. I this has been covered, please point me in the right direction. I have a y plan system with a Vaillant ecotec boiler set up with a 3rd gen Nest. When turning...
  4. T

    Vaillant diverter valve works but not when hot water tank is refilled and tap open...

    Hello, I have a vaillant boiler plus a hot water tank. I changed diverter valve 3 years ago because it did not move correctly. For a month now I have had a new problem with this diverter valve but slightly different and I can not find the cause. The valve works perfectly for central heating /...
  5. C

    (Combi) Bath Mixer Tap Hot Then Lukewarm

    Hi, We have a problem with our bath mixer tap. When you run the hot tap it does get hot for a bit but then goes lukewarm.. eventually hot again but due to the constant cycling between hot and lukewarm you can't run a hot bath. The central heating is off, the combi boiler is a Vaillant 835/2 E...
  6. A

    Valliant AquaPlus VUI 362-7 Help!

    Hi all, After some help with my AquaPlus boiler. The boiler seems to be rising pressure on the gauge with the cold water service valve open as normal. I’ve closed the valve currently without use of the boiler as I’m getting a constant trickle of water through the outlet pipe to my driveway...
  7. V

    Vaillant Ecotec Pro 28 & Drayton Wiser thermostat kit 1

    Hi All, I would like to replace a Honeywell room thermostat with a Drayton Wiser (I'll also be replacing the radiator valves later). Can I just confirm that: N & L stay the same 2nd L to A loop in the Honeywell should now be L to 1 in the Drayton 2 in the Drayton stays empty B in the Honeywell...
  8. D

    Vaillant Ecotec plus 937 with Opentherm and Evohome

    Hi All, I'm looking to wire up our Ecotec 937 plus with Opentherm and Evohome. So far I can source the VR33 module and have located the X31 interface on the PCB where this should be plugged in. Unfortunately it appears to have another connection already plugged into this serving the shift load...
  9. L

    WiFi relay and Vaillant Combi boiler heating

    Hi guys, I am thinking of getting my heating control a little bit smarter. Currently, I have "old" Salus RF thermostat with touch ring, but not connected to any hub, so I can't control it outside of my house. I was thinking about getting micro usb powered d1mini development board with relay...
  10. D

    Accuracy of Vaillant vSmart internet temperature

    hi all, I am thinking about replacing My Vailant VRC470 with a Vaillant vSmart controller but I am concerned that the WC I have at the moment using a sensor on the north face of my property is far more accurate than the general weather data derived from the internet that the vSmart uses. Am I...
  11. N

    Advice - Nest and Vaillant Ecotec Plus Wiring

    Hi all, I'm wondering if someone can validate my wiring plan for my Nest + Vaillant Ecotec Plus boiler. It's an early Gen1 nest so only does the heating. The boiler is new and the installers were confused by the older Nest so at the moment the Heating and Hot Water both have to be on all the...
  12. J

    Vaillant boiler pressure

    Evening, Having some trouble with my Vaillant Ecotec Plus 418, which is showing a F22 error code - low water pressure. Sadly there isn't a filling loop that allows me to repressurise it. Does anyone know how I might get around this? When I reset it, it starts up but then winds down quite...
  13. J

    Vaillant ecoTEC under gassed 14milibar - pipe too thin?

    Hi. Got a Vaillant ecoTEC pro 28 combi boiler which is about 10 years old. I had a plumber come today as our boiler continually turns off with a F.62 warning and red light, have to press the flame button with a cross on it to reset and get hot water back. The pressure also continually rises to...
  14. J

    Vaillant Ecotec Pro 28

    Hey people small issue here on my Boiler. It’s a Vaillant Ecotec Pro 28, yesterday I drained the central heating system as I was having some pipe work done for a new towel rad in the bathroom. Also turned the mains water off and opened taps to get all the water out the pipes forgot to turn the...
  15. L

    Vaillant Turbomax pressure valve stuck?

    Hi all, I believe we have a Vaillant Turbomax boiler although I'm unsure of the exact model number. The pressure has been low for a couple of years but only recently on a couple of occasions it has failed to fire up. I just pressed a button and it switched back on immediately. A gas safety...
  16. E

    Vaillant d.0

    Hello, having a bit of a 'mare with this one, so though I would seek out some help. I have a Vaillant ecotech pure installed recently (the version that fits in a cupboard) around 24kw I think. It seems to be using a huge amount of energy but never quite getting the rooms warm. I'm looking into...
  17. dpm_dpmartin

    Vaillant TURBOmax Plus - filling?

    I have been sent this picture of a Vaillant boiler where the pressure needle is down at the bottom. I advised my friend that it (obviously, doh!) needs re-filling and I superciliously (super-silly?) told my friend there should be something obvious on the underside... but - sadly - this picture...
  18. thegingerwinner

    Vaillant boiler - hot water turning cold mid flow

    I've got an issue with my Vaillant TURBOmax 828E combi boiler and I am hoping someone might be able to help me understand the likely cause of the problem before I call out an engineer. The hot water occasionally goes cold mid flow. I first noticed this when taking a shower, so I had a look at...
  19. T

    Vaillant boiler - how to fill/pressurize this configuration

    Hi, I am getting the F22 message on my Vaillant hr Solide boiler (VHR Netherlands version). The bar reading is low too at 0.5bar. So I would like to top it up. In the attached image, you can see there are two valves, black on the right attached to the yellow pipe (nothing attached on the...
  20. B

    Vaillant ecotec 838 with Nest

    Hi all, Just wandering is the nest compatible with the vaillant ecotec 838 plus combi boiler? And if so, does anyone have an appropriate link with how the wiring should be undertaken. The boiler is a brand new install with no current thermostat installed. Any help and advice would be largely...
Back